Accessoires voor transformatoren play an essential role in improving transformer safety, monitoring performance, and extending service life. A power transformer is not only composed of the core, wikkelingen, and insulation system; reliable operation also depends on the correct selection and performance of transformer accessories such as Buchholz relays, bussen, silicagel ontluchters, and oil level indicators.A power transformer is not only composed of the core, wikkelingen, and insulation system. The reliability of a transformer also depends heavily on the performance of its accessories.
Transformer accessories are responsible for:
- Monitoring transformer operating conditions;
- Protecting against abnormal operation;
- Maintaining insulation performance;
- Providing early warnings before serious failures occur.
Echter, selecting the correct transformer accessories is not always straightforward.
Many problems in transformer installation and maintenance are caused by incorrect accessory selection, zoals:
- Wrong voltage rating;
- Incorrect mounting dimensions;
- Unsuitable material selection;
- Missing communication requirements;
- Poor compatibility with the transformer design.
For engineers, understanding the key selection parameters of transformer accessories can significantly improve transformer reliability and reduce maintenance costs.

1. Transformer Accessories Selection Starts with Transformer Design
Before selecting any accessory, engineers should first understand the transformer basic parameters.
The following information is normally required:
| Parameter | Voorbeeld |
|---|---|
| Transformer type | In olie ondergedompelde transformator |
| Rated voltage | 11kV / 33kV / 66kV |
| Rated capacity | 1000kVA |
| Frequentie | 50Hz / 60Hz |
| Cooling method | ONAN / AAN UIT |
| Installation location | Indoor / Outdoor |
| Environmental condition | Normal / Coastal / Industrieel |
Accessories are not independent components. They must match the transformer design.
Bijvoorbeeld:
A Buchholz relay installed on a 33kV power transformer requires different specifications compared with one used on a small distribution transformer.
2. How to Select a Buchholz Relay?
A Buchholz relay is one of the most important protection devices for oil immersed transformers equipped with a conservator tank.
Het detecteert:
- Ophoping van gas;
- Oil flow caused by internal faults;
- Serious insulation problems.
Key Selection Parameters
2.1 Pijpdiameter
The relay size must match the connection pipe between:
Transformer tank → Conservator tank
Veel voorkomende maten zijn onder meer:
- DN25
- DN50
- DN80
Incorrect pipe size may affect oil flow detection accuracy.
2.2 Transformer Capacity
Large transformers generally require higher sensitivity and stronger mechanical design.
Selection depends on:
- Transformer rating;
- Oil volume;
- Internal fault protection requirements.
2.3 Alarm and Trip Contacts
Engineers should confirm:
- Number of contacts;
- Contact rating;
- Signal type.
Typical requirements:
- Alarm contact;
- Trip contact.
For modern substations, remote monitoring capability is increasingly required.

3. Transformer Bushing Selection Parameters
Transformer bushings provide electrical connection between internal windings and external circuits.
Incorrect bushing selection may cause:
- Isolatie mislukt;
- Oververhitting;
- Gedeeltelijke ontlading.
Important Parameters
Nominale spanning
The bushing voltage class must match the transformer system voltage.
Voorbeeld:
| Transformer Voltage | Recommended Bushing Class |
|---|---|
| 10kV | 12kV |
| 35kV | 40.5kV |
| 110kV | 126kV |
Nominale stroom
The current rating must be higher than the transformer operating current.
Insufficient current capacity may cause overheating.
Creepage Distance
For outdoor transformers, creepage distance is critical.
Higher pollution areas require longer creepage distance.
Environmental factors include:
- Coastal salt;
- Industriële vervuiling;
- Desert dust.
4. Selecting the Right Silica Gel Breather
A silica gel breather protects transformer insulation by preventing moisture from entering through the conservator tank.
Key Parameters
4.1 Transformer Oil Volume
The breather size should match the transformer oil expansion volume.
Small breathers may not provide sufficient breathing capacity.
4.2 Silica Gel Capacity
Common considerations:
- Amount of silica gel;
- Moisture absorption capacity;
- Easy replacement design.
4.3 Maintenance Requirements
A good breather design should allow:
- Easy silica gel replacement;
- Visual moisture inspection;
- Reliable sealing.
5. Oil Level Indicator Selection
Oil level indicators monitor transformer oil level changes caused by temperature variation.
Selection Factors:
Display Type
Options include:
- Mechanical indicator;
- Magnetic oil level gauge;
- Remote signal type.
Alarm Function
For critical transformers, engineers may require:
- Low oil level alarm;
- Remote monitoring output.
Installation Position
Before ordering, confirm:
- Mounting flange;
- Connection size;
- Indicator direction.
6. Pressure Relief Device Selection
A pressure relief device protects transformers from dangerous internal pressure increases.
When an internal fault occurs, gas generation can rapidly increase pressure inside the tank.
The relief device releases pressure to prevent tank deformation or explosion.
Important Parameters:
| Parameter | Importance |
|---|---|
| Opening pressure | Protection level |
| Flow capacity | Pressure release speed |
| Mounting size | Installation compatibility |
| Alarm contact | Remote warning |
7. Consider International Standards
For export transformer projects, standards are extremely important.
Common standards include:
IEC Standards
- IEC 60076 — Power transformers
- IEC 60137 — Insulated bushings
- IEC 60214 — Tap changers
IEEE Standards
Commonly required in North American projects.
Before quotation, engineers should confirm:
- Required standard;
- Testing requirements;
- Certification documents.

8. Common Mistakes When Selecting Transformer Accessories
Mistake 1: Selecting Only Based on Price
Low-cost accessories may lead to:
- Shorter service life;
- Higher maintenance cost;
- Unexpected failures.
Mistake 2: Ignoring Installation Dimensions
Electrical parameters may be correct, but mechanical dimensions may not match.
Always confirm:
- Drawings;
- Mounting holes;
- Connection dimensions.
Mistake 3: Not Considering Future Maintenance
A transformer may operate for 25–40 years.
Accessories should be selected considering:
- Replacement availability;
- Spare parts;
- Maintenance convenience.
9. Engineer Checklist Before Ordering Transformer Accessories
Before purchasing, confirm:
☑ Transformer rated voltage
☑ Transformer capacity
☑ Accessory model
☑ Installation drawing
☑ Applicable IEC/IEEE standard
☑ Required testing report
☑ Alarm and communication requirements
☑ Environmental conditions
Manufacturer Insight
As a transformer manufacturer and transformer accessories supplier, PDDN recommends that customers provide complete technical information before selecting accessories.
For OEM and replacement projects, the following documents are helpful:
- Transformer nameplate;
- Existing accessory model;
- Installation drawing;
- Technical specification;
- Required standard.
Proper selection during the engineering stage can prevent installation problems and improve transformer operating reliability.
Over PDDN
PDDN is the online platform ofLuoyang Datang Energietechnologie Co., Ltd., a trusted manufacturer and global supplier ofstroomtransformatoren, accessoires voor transformatoren, switchgear components, energieopslagsystemen op batterijen (BESS), and EV charging solutions. Since 2015, we have supported utility companies, EPC-aannemers, and industrial customers worldwide with reliable products, OEM/ODM services, and technical expertise.