Driefasige 34,5 kV op pad gemonteerde MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequentie

PRODUCTPARAMETERS

Beschrijving
VRAAG EEN OFFERTE AAN

Beschrijving

Overview of Three-Phase 34.5kV Pad Mounted MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequentie

Driefasige 34,5 kV op pad gemonteerde MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequency is an enclosed, elektrische distributietransformator op grondniveau die gewoonlijk ondergronds wordt gebruikt (En) energiesystemen. Het verlaagt de primaire hoogspanningselektriciteit (bijv., 15kV of 25 kV) naar een lagere secundaire spanning (bijv., 120/240V of 480V) voor een veilige distributie naar woonwijken, commerciƫle gebouwen, en industrieparken. Het is robuust, afsluitbare stalen behuizing maakt het veilig voor openbare ruimtes.

Features of Three-Phase 34.5kV Pad Mounted MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequentie

Behuizing op grondniveau: Een vergrendeld, fraudebestendig, weerbestendige stalen kast die de interne componenten beschermt en de openbare veiligheid garandeert.

Ondergrondse kabelverbindingen: Ontworpen voor eenvoudige aansluiting op ondergrondse primaire aansluitingen (hoogspanning) en secundair (laagspanning) kabels via compartimenten met ingebouwde bussen.

Compartimentering: Verschillend, geĆÆsoleerde compartimenten voor hoogspannings- en laagspanningscomponenten, het vergroten van de veiligheid tijdens onderhoud.

Ventilatie: Ontworpen met lamellen of andere ventilatiesystemen om een ​​goede warmteafvoer van de transformatorkern en spoelen mogelijk te maken.

Hijsogen: GeĆÆntegreerde hijsogen voor eenvoudige en veilige installatie en vervanging met behulp van een kraan of takel.

Fraudebestendige hardware: Afsluitbare deuren met speciale grendels om ongeautoriseerde toegang te voorkomen.

Gezekerde schakelaars: Bevat vaak gezekerde scheidingsschakelaars voor circuitbescherming en veilige isolatie.

Stichting Pad: GeĆÆnstalleerd op een betonnen pad (“op pad gemonteerd”) een stal te bieden, vlakke basis.

Specifications of Three-Phase 34.5kV Pad Mounted MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequentie

These Three-Phase Pad Mounted Transformers manage tool and high voltage conversion. They run at 34.5 kilovolts on the main side. The additional side supplies lower voltages: 13.8 kilovolt. This arrangement prevails for utility distribution networks.

A number of capability choices exist. Systems are readily available in 500 kVA, 1000 kVA, 1250 kVA, 1500 kVA, En 2000 kVA (2 MVA). The specific capability relies on the application’s power needs. The conventional regularity is 60 Hertz.

The transformers are pad-mounted. This suggests they remain on a concrete slab outdoors. This style safeguards the interior elements. It also permits safe gain access to for maintenance. De behuizing is robuust. It holds up against climate and safeguards against unauthorized gain access to.

Voltage conversion is the core function. The key winding approves 34.5 kV. The additional winding results 13.8 kV. This actions down the voltage for local circulation. The transformers transfer power efficiently. They decrease power losses.

Building complies with market criteria. The core makes use of state-of-the-art electrical steel. Wikkelingen zijn van koper of aluminium. The choice relies on style. The container holds protecting oil. Deze olie koelt de transformator af. It also gives electric insulation.

These units serve industrial and commercial facilities. They feed power to large buildings or manufacturing facilities. Dependability is crucial. The style focuses on long service life. Er is minimaal onderhoud vereist. They are a useful solution for stepping down 34.5 kV to 13.8 kV.

Applications of Three-Phase 34.5kV Pad Mounted MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequentie

Three-phase pad installed transformers deal with tool and high voltage power. They step down power safely. Typical key voltages are 34.5 kV of 13.8 kV. Common secondary results are 220v, 380v, 440v, or 480v. These devices run at 60Hz frequency. They are constructed for requiring commercial and business power circulation. You see them anywhere power needs tipping down reliably.

These transformers can be found in many dimensions. Criterion capabilities include 500KVA, 1000KVA, 1250KVA, 1500KVA, and 2MVA. This variety fulfills different tons requirements. Smaller units suit structures or light sector. Larger systems power large manufacturing facilities or complexes. The pad-mounted design is crucial. It puts the transformer securely on a concrete pad outside. This setup keeps high voltage away from individuals. It shields the device. It simplifies accessibility for utility staffs. Onderhoud is eenvoudiger. Safety and security boosts substantially.

Their applications are widespread. They power big factory. They run heavy machinery successfully. They supply necessary power to hospitals and information facilities. These areas require continuous, nette kracht. They feed huge industrial buildings like shopping malls. They support water treatment plants and pumping stations. They are essential for extracting operations and oil fields. They attach renewable energy projects like solar farms to the grid. They distribute power within huge universities or universities. They offer the backbone for utility firm circulation networks. Dependability is critical everywhere.

Deze transformatoren zijn sterk. They withstand extreme weather conditions. They manage dust, vocht, en extreme temperaturen. Their rooms are durable steel. They prevent unauthorized gain access to. They shield internal components. This makes sure lengthy service life. Performance matters also. Modern styles minimize power loss throughout voltage conversion. This conserves operating costs over time. They are crafted for reliable performance year after year. They form a crucial link in the power chain.

Bedrijfsprofiel

PDDN Foto-elektron Technologie Co., Ltd. is een van de toonaangevende ondernemingen op het gebied van vermogenselektronicatechnologie en energieproducten, dat volledig betrokken is bij de ontwikkeling van omvormers voor zonne-energie, transformatoren, spanningsregelaars, verdeelkasten, thyristoren, modules, diodes, verwarmers, en andere elektronische apparaten of halfgeleiders. We zullen ons inzetten om gebruikers hoogwaardige kwaliteit te bieden, efficiĆ«nte producten en attente service.

Het accepteert betaling via creditcard, T/T, Westelijke Unie, en PayPal. PDDN verzendt de goederen via FedEx naar klanten in het buitenland, DHL, over zee, of door de lucht. If you want high-quality Three-Phase 34.5kV Pad Mounted MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequentie, Stuur ons alstublieft vragen; wij zullen hier zijn om u te helpen.


Betaalmethoden

L/C, T/T, Western Unie, Paypal, Creditcard enz.


Verzending

Over zee, door de lucht, per expresse, zoals klanten vragen.


Opslagomstandigheden

1) Bewaren in een droge omgeving bij kamertemperatuur.

2) Vermijd vocht en hoge temperaturen.

3) Gebruik onmiddellijk na het openen van de binnenverpakking.

5 FAQs of Three-Phase 34.5kV Pad Mounted MV&HV-transformatoren 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequentie

What safety features protect these transformers?
These units include multiple safety systems. They have pressure relief devices. They have fault indicators. They use mineral oil for cooling and insulation. De tank is volledig afgedicht. Dit voorkomt lekkages. It also keeps moisture out. They meet strict ANSI/IEEE standards.

Welke ruimte is nodig voor installatie?
You need a flat, solid concrete pad. The pad must support the transformer’s weight. Laat er voldoende ruimte omheen. Workers need space for maintenance. Keep vegetation away. Follow the exact dimensions in our manual. Local codes might add requirements.

Are these transformers certified?
Ja. They carry standard industry certifications. They meet ANSI C57.12.26 and IEEE C57.12.00. We build them for UL standards. Third-party labs test them. This confirms safety and performance. Ask for the test reports.

Can I get custom voltage taps?
Ja. We offer optional voltage taps. Common secondary voltages are 220V, 380V, 440V, 480V. Vertel ons uw exacte behoeften. We can adjust the primary or secondary taps. This ensures compatibility with your grid. Request this when ordering.

Welk onderhoud is er nodig?
Heel weinig. These are low-maintenance units. The sealed tank design helps. Check oil levels yearly. Zoek naar lekkages of schade. Clean the exterior surfaces. Monitor the fault indicators. Wij bieden een volledige onderhoudsgids. Follow it for long life.

VRAAG EEN OFFERTE AAN

VRAAG EEN OFFERTE AAN