Leverandør av elektroniske komponenter | Transformatorer, Induktorer, Invertere
PRODUKTPARAMETRE
Beskrivelse
Overview of Three-Phase 34.5kV Pad Mounted MV&HV Transformatorer 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frekvens
Trefaset 34,5 kV padmontert MV&HV Transformatorer 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frequency is an enclosed, bakkenivå elektrisk distribusjonstransformator som vanligvis brukes i undergrunnen (og) kraftsystemer. Den trapper ned primær høyspentelektrisitet (f.eks., 15kV eller 25kV) til en lavere sekundærspenning (f.eks., 120/240V eller 480V) for trygg distribusjon til boligområder, næringsbygg, og industriparker. Den er robust, låsbart stålkabinett gjør det trygt for offentlige områder.
Features of Three-Phase 34.5kV Pad Mounted MV&HV Transformatorer 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frekvens
Innkapsling på bakkenivå: A låst, manipulasjonssikker, værbestandig stålskap som beskytter de interne komponentene og sikrer offentlig sikkerhet.
Underjordiske kabeltilkoblinger: Designet for enkel tilkobling til underjordisk primær (høy spenning) og sekundær (lavspent) kabler via rom med innebygde gjennomføringer.
Oppdeling: Skille, isolerte rom for høyspennings- og lavspentkomponenter, øke sikkerheten under vedlikehold.
Ventilasjon: Designet med lameller eller andre ventilasjonssystemer for å tillate riktig varmeavledning fra transformatorkjernen og spolene.
Løftekroker: Integrerte løfteører for enkel og sikker montering og utskifting med kran eller talje.
Inngrepssikker maskinvare: Låsbare dører med spesialbolter for å hindre uautorisert tilgang.
Fusede brytere: Inkluderer ofte sikringsbrytere for kretsbeskyttelse og sikker isolasjon.
Pad Foundation: Installert på en betongpute (“putemontert”) å gi en stall, nivå base.
Specifications of Three-Phase 34.5kV Pad Mounted MV&HV Transformatorer 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frekvens
These Three-Phase Pad Mounted Transformers manage tool and high voltage conversion. They run at 34.5 kilovolts on the main side. The additional side supplies lower voltages: 13.8 kilovolt. This arrangement prevails for utility distribution networks.
A number of capability choices exist. Systems are readily available in 500 kVA, 1000 kVA, 1250 kVA, 1500 kVA, og 2000 kVA (2 MVA). The specific capability relies on the application’s power needs. The conventional regularity is 60 Hertz.
The transformers are pad-mounted. This suggests they remain on a concrete slab outdoors. This style safeguards the interior elements. It also permits safe gain access to for maintenance. Kabinettet er robust. It holds up against climate and safeguards against unauthorized gain access to.
Voltage conversion is the core function. The key winding approves 34.5 kV. The additional winding results 13.8 kV. This actions down the voltage for local circulation. The transformers transfer power efficiently. They decrease power losses.
Building complies with market criteria. Kjernen bruker toppmoderne elektrisk stål. Viklinger er av kobber eller aluminium. The choice relies on style. The container holds protecting oil. Denne oljen kjøler ned transformatoren. It also gives electric insulation.
These units serve industrial and commercial facilities. They feed power to large buildings or manufacturing facilities. Pålitelighet er avgjørende. The style focuses on long service life. Minimalt vedlikehold er nødvendig. They are a useful solution for stepping down 34.5 kV to 13.8 kV.
Applications of Three-Phase 34.5kV Pad Mounted MV&HV Transformatorer 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frekvens
Three-phase pad installed transformers deal with tool and high voltage power. They step down power safely. Typical key voltages are 34.5 kV eller 13.8 kV. Common secondary results are 220v, 380v, 440v, or 480v. These devices run at 60Hz frequency. They are constructed for requiring commercial and business power circulation. You see them anywhere power needs tipping down reliably.
These transformers can be found in many dimensions. Criterion capabilities include 500KVA, 1000KVA, 1250KVA, 1500KVA, and 2MVA. This variety fulfills different tons requirements. Smaller units suit structures or light sector. Larger systems power large manufacturing facilities or complexes. The pad-mounted design is crucial. It puts the transformer securely on a concrete pad outside. This setup keeps high voltage away from individuals. It shields the device. It simplifies accessibility for utility staffs. Maintenance is simpler. Safety and security boosts substantially.
Their applications are widespread. They power big factory. They run heavy machinery successfully. They supply necessary power to hospitals and information facilities. These areas require continuous, ryddig kraft. They feed huge industrial buildings like shopping malls. They support water treatment plants and pumping stations. They are essential for extracting operations and oil fields. They attach renewable energy projects like solar farms to the grid. They distribute power within huge universities or universities. They offer the backbone for utility firm circulation networks. Dependability is critical everywhere.
Disse transformatorene er tøffe. They withstand extreme weather conditions. They manage dust, fuktighet, and temperature level extremes. Their rooms are durable steel. They prevent unauthorized gain access to. They shield internal components. This makes sure lengthy service life. Performance matters also. Modern styles minimize power loss throughout voltage conversion. This conserves operating costs over time. They are crafted for reliable performance year after year. They form a crucial link in the power chain.
Bedriftsprofil
PDDN Photoelectron Technology Co., Ltd. er en av de ledende foretakene innen kraftelektronikkteknologi og kraftprodukter, som er fullt involvert i utviklingen av solcelle-omformere, transformatorer, spenningsregulatorer, distribusjonsskap, tyristorer, moduler, dioder, varmeovner, og andre elektroniske enheter eller halvledere. Vi vil være forpliktet til å gi brukerne høy kvalitet, effektive produkter og hensynsfull service.
Den aksepterer betaling med kredittkort, T/T, West Union, og Paypal. PDDN vil sende varene til kunder i utlandet gjennom FedEx, DHL, til sjøs, eller med fly. If you want high-quality Three-Phase 34.5kV Pad Mounted MV&HV Transformatorer 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frekvens, vennligst send oss forespørsler; vi vil være her for å hjelpe deg.
Betalingsmetoder
L/C, T/T, Western Union, Paypal, Kredittkort etc.
Forsendelse
Ved sjøen, med fly, ved ekspress, som kundene ber om.
Oppbevaringsbetingelser
1) Oppbevares i et tørt miljø ved romtemperatur.
2) Unngå fuktighet og høy temperatur.
3) Brukes umiddelbart etter at den indre pakningsposen er åpnet.
5 FAQs of Three-Phase 34.5kV Pad Mounted MV&HV Transformatorer 13,8kv 500KVA 1000KVA 1250 Kva 1500KVA 2MVA 220v/380v/440v/480v 60Hz Frekvens
What safety features protect these transformers?
These units include multiple safety systems. De har trykkavlastningsanordninger. They have fault indicators. They use mineral oil for cooling and insulation. The tank is fully sealed. Dette forhindrer lekkasjer. Det holder også fuktighet ute. They meet strict ANSI/IEEE standards.
Hvilken plass er nødvendig for installasjon?
You need a flat, solid concrete pad. The pad must support the transformer’s weight. La nok plass rundt den. Workers need space for maintenance. Keep vegetation away. Follow the exact dimensions in our manual. Local codes might add requirements.
Are these transformers certified?
Ja. They carry standard industry certifications. They meet ANSI C57.12.26 and IEEE C57.12.00. We build them for UL standards. Third-party labs test them. Dette bekrefter sikkerhet og ytelse. Be om testrapportene.
Can I get custom voltage taps?
Ja. We offer optional voltage taps. Common secondary voltages are 220V, 380V, 440V, 480V. Fortell oss dine nøyaktige behov. We can adjust the primary or secondary taps. This ensures compatibility with your grid. Request this when ordering.
Hvilket vedlikehold som kreves?
Veldig lite. These are low-maintenance units. The sealed tank design helps. Check oil levels yearly. Look for leaks or damage. Clean the exterior surfaces. Monitor the fault indicators. We provide a full maintenance guide. Follow it for long life.
BE ET TILBUD
RELATERTE PRODUKTER

Factory Direct 250kva 10KV American Type MV&HV Transformers Competitive Pad Mounted 380V 110V 400V 6KV 440V 480V 50Hz 60Hz