After installing the photovoltaic system, the most important concern for users is the power generation, as it directly affects their investment return. Many factors affect power generation, including the quality of components, インバータ, ケーブル, installation orientation angle, tilt angle, ほこり, shadow obstruction, component and inverter ratio system scheme, line design, 工事, grid voltage, and other factors. The following mainly discusses the impact of the ratio of components and インバータ on the system's power generation.

Because inverters only account for about 5% of the cost of photovoltaic systems, reducing inverter investment through component overmatching is not only not cost-effective but also brings other problems. To comprehensively consider factors such as lighting conditions, installation site, components, とインバータ, scientific design should be carried out, tailored to local conditions, and specific problem-specific analysis should be carried out rather than unthinkingly utilizing the overmatching ability of inverters.

The inverter has multiple MPPTs, each of which tracks independently to be connected to different strings. The inclination angle of the string can also be different, but each MPPT branch has a current limit, such as a 20kW inverter and two MPPTs, and each MPPT circuit can output up to 11kW at the rated working voltage. If multiple connections are made, the power will be limited. The customer connected three channels, with an input power of 15.12kW and an additional 4.12kW. When the weather is good, and the sun is strong, the power will be limited, so losing 10 kWh of electricity in a day is not surprising.

The working voltage is around the rated working voltage of the inverter, resulting in the highest efficiency. For single-phase 220V output inverters, their rated input voltage is 360V; The rated input voltage of a three-phase 380V output inverter is 650V. 例えば, a 3kW inverter with a 260W component and a working voltage of 30.5V, with 12 modules and a working voltage of 366V, is the optimal power of 3.12kW. The 30KW inverter is equipped with 260W components, connected to 126 components, 21 strings in each circuit, and a voltage of 640.5V. The optimal total power is 32.76kW. The greater the difference between the string MPPT voltage and the optimal voltage of the inverter (low or high), the lower the efficiency. 例えば, when a single-phase inverter is string-matched to 260V or 460V, the efficiency is only about 90% of the optimal voltage.
Several points to note when configuring components and inverters
1) We cannot simply emphasize component overfitting to reduce the cost of inverters. We need to analyze specific issues based on the actual situation.
2) Each inverter's MPPT circuit also has limitations and cannot be exceeded.
3) The string voltage should be within the optimal voltage range of the inverter as much as possible, as both low and high voltages can significantly impact power generation.
High-quality Supplier
PDDN フォトエレクトロン テクノロジー株式会社, 株式会社. 研究に焦点を当てています, 発達, パワーエレクトロニクス技術の応用と高品質な変圧器の提供に注力しています。, サイリスタ, およびその他のパワー製品. 当社は主に太陽光発電用パワーコンディショナーを扱っています, 変圧器, 電圧レギュレータ, 配電盤, サイリスタ, モジュール, ダイオード, ヒーター, およびその他の電子デバイスまたは半導体. PDDN Photoelectron Technology Co.が提供する電子デバイスおよび半導体製品, 株式会社. 高効率の特性を持っています, 安全性, そして信頼性. 電力システムで広く使用されています, 産業用制御, エネルギー管理, その他の分野.