Trafo

Trafo (محول) – Comprehensive Guide

1. Main Types of Trafo

(1) By Cooling Method
  • Oil-Immersed Trafo

    • Uses insulating oil for cooling, suitable for high-voltage and high-capacity applications (على سبيل المثال, grid substations).

    • Common Models: أونان (natural cooling), تشغيل إيقاف (تبريد الهواء القسري), أوفاف (forced oil and air cooling).

  • Dry-Type Trafo

    • Oil-free design, insulated by air or resin, ideal for fire-sensitive environments (على سبيل المثال, المستشفيات, مراكز البيانات).

    • Common Models: بنك التسليف والادخار (epoxy resin-cast), سان جرمان (open-type).

(2) By Application
  • Distribution Trafo

    • Voltage levels: 10kV/0.4kV, used for end-user power supply (على سبيل المثال, المناطق السكنية, المصانع).

  • Power Trafo

    • Voltage levels ≥110kV, used in transmission networks (على سبيل المثال, substation main transformers).

  • Special Trafo

    • Includes rectifier transformers (for electrolysis), mining transformers (explosion-proof design), إلخ.

                        4_副本_副本 

2. المواصفات الرئيسية

Parameterوصف
القدرة المقدرةعلى سبيل المثال, 100كيلو فولت أمبير, 5000كيلو فولت أمبير; must be calculated based on load.
Voltage RatioInput/output voltage (على سبيل المثال, 10kV/0.4kV).
Impedance VoltageTypically 4%~10%, affects short-circuit current.
Connection Groupعلى سبيل المثال, داين11 (common for distribution), Yyn0 (balanced low-voltage loads).
Cooling Methodأونان, تشغيل إيقاف, OFWF (oil-immersed); تشغيل/إيقاف (النوع الجاف).
Efficiency ClassChinese standard (غيغابايت 20052): فصل 1 (highest efficiency), فصل 2, فصل 3.

3. التطبيقات

  • Power Systems: Voltage step-up/down, grid interconnection.

  • صناعي: Power supply for motors, أفران (custom impedance may be required).

  • Renewable Energy: PV/wind grid integration (must withstand harmonics).

  • Rail Transit: Traction transformers (25kV/50Hz).

4. Selection Guide

  • Indoor Installation: Prefer dry-type (fireproof) or fully sealed oil-immersed.

  • Outdoor Installation: Oil-immersed (protection class ≥IP55).

  • High Load Fluctuations: Choose models with strong overload capacity (على سبيل المثال, ONAF cooling).

  •                  2_副本

5. التعليمات

Q: How to choose between oil-immersed and dry-type transformers?
أ: Oil-immersed offers lower cost and higher capacity but requires fire protection; dry-type is safer for confined spaces.

Q: How to calculate required capacity?
أ: Sum all load power (كيلو فولت أمبير) and reserve 20%~30% margin.

Q: How to reduce transformer noise?
أ: Select low-noise designs (على سبيل المثال, step-lap core) or install soundproof enclosures.

تحديثات النشرة الإخبارية

أدخل عنوان بريدك الإلكتروني أدناه واشترك في نشرتنا الإخبارية