Trafo

Trafo (Transformator) – Comprehensive Guide

1. Main Types of Trafo

(1) By Cooling Method
  • Oil-Immersed Trafo

    • Uses insulating oil for cooling, suitable for high-voltage and high-capacity applications (f.eks., grid substations).

    • Common Models: ONAN (natural cooling), PÅ AV (forced air cooling), OFAF (forced oil and air cooling).

  • Dry-Type Trafo

    • Oil-free design, insulated by air or resin, ideal for fire-sensitive environments (f.eks., sykehus, datasentre).

    • Common Models: SCB (epoxy resin-cast), SG (open-type).

(2) By Application
  • Distribution Trafo

    • Voltage levels: 10kV/0.4kV, used for end-user power supply (f.eks., residential areas, fabrikker).

  • Power Trafo

    • Voltage levels ≥110kV, used in transmission networks (f.eks., substation main transformers).

  • Special Trafo

    • Includes rectifier transformers (for electrolysis), mining transformers (explosion-proof design), osv.

                        4_副本_副本 

2. Key Specifications

ParameterBeskrivelse
Nominell kapasitetf.eks., 100kVA, 5000kVA; must be calculated based on load.
SpenningsforholdInput/output voltage (f.eks., 10kV/0.4kV).
Impedance VoltageTypically 4%~10%, affects short-circuit current.
Connection Groupf.eks., Dyn11 (common for distribution), Yyn0 (balanced low-voltage loads).
KjølemetodeONAN, PÅ AV, OFWF (oil-immersed); PÅ/AV (dry-type).
Efficiency ClassChinese standard (GB 20052): Klasse 1 (highest efficiency), Klasse 2, Klasse 3.

3. Søknader

  • Power Systems: Voltage step-up/down, grid interconnection.

  • Industriell: Power supply for motors, ovner (custom impedance may be required).

  • Renewable Energy: PV/wind grid integration (must withstand harmonics).

  • Rail Transit: Traction transformers (25kV/50Hz).

4. Selection Guide

  • Indoor Installation: Prefer dry-type (fireproof) or fully sealed oil-immersed.

  • Outdoor Installation: Oil-immersed (protection class ≥IP55).

  • High Load Fluctuations: Choose models with strong overload capacity (f.eks., ONAF cooling).

  •                  2_副本

5. FAQ

Q: How to choose between oil-immersed and dry-type transformers?
EN: Oil-immersed offers lower cost and higher capacity but requires fire protection; dry-type is safer for confined spaces.

Q: How to calculate required capacity?
EN: Sum all load power (kVA) and reserve 20%~30% margin.

Q: How to reduce transformer noise?
EN: Select low-noise designs (f.eks., step-lap core) or install soundproof enclosures.

Nyhetsbrevoppdateringer

Skriv inn din e-postadresse nedenfor og abonner på vårt nyhetsbrev