Trafo (Transformador) – Comprehensive Guide
1. Main Types of Trafo
(1) By Cooling Method
Oil-Immersed Trafo
Uses insulating oil for cooling, suitable for high-voltage and high-capacity applications (por exemplo, grid substations).
Common Models: ONAN (natural cooling), LIGADO DESLIGADO (resfriamento de ar forçado), OFAF (forced oil and air cooling).
Dry-Type Trafo
Oil-free design, insulated by air or resin, ideal for fire-sensitive environments (por exemplo, hospitais, centros de dados).
Common Models: SCB (epoxy resin-cast), SG (open-type).
(2) By Application
Distribution Trafo
Níveis de tensão: 10kV/0,4kV, used for end-user power supply (por exemplo, residential areas, fábricas).
Power Trafo
Voltage levels ≥110kV, used in transmission networks (por exemplo, substation main transformers).
Special Trafo
Includes rectifier transformers (for electrolysis), mining transformers (explosion-proof design), etc..
2. Especificações principais
| Parameter | Descrição |
|---|---|
| Capacidade nominal | por exemplo, 100kVA, 5000kVA; must be calculated based on load. |
| Relação de tensão | Input/output voltage (por exemplo, 10kV/0,4kV). |
| Tensão de impedância | Typically 4%~10%, affects short-circuit current. |
| Connection Group | por exemplo, Dyn11 (common for distribution), Sim0 (balanced low-voltage loads). |
| Método de resfriamento | ONAN, LIGADO DESLIGADO, OFWF (oil-immersed); LIGADO/DESLIGADO (tipo seco). |
| Efficiency Class | Chinese standard (GB 20052): Aula 1 (highest efficiency), Aula 2, Aula 3. |
3. Aplicativos
Power Systems: Voltage step-up/down, grid interconnection.
Industrial: Power supply for motors, fornos (custom impedance may be required).
Renewable Energy: PV/wind grid integration (must withstand harmonics).
Rail Transit: Traction transformers (25kV/50Hz).
4. Selection Guide
Indoor Installation: Prefer dry-type (fireproof) or fully sealed oil-immersed.
Outdoor Installation: Oil-immersed (protection class ≥IP55).
High Load Fluctuations: Choose models with strong overload capacity (por exemplo, ONAF cooling).

5. Perguntas frequentes
P: How to choose between oil-immersed and dry-type transformers?
UM: Oil-immersed offers lower cost and higher capacity but requires fire protection; dry-type is safer for confined spaces.
P: How to calculate required capacity?
UM: Sum all load power (kVA) and reserve 20%~30% margin.
P: How to reduce transformer noise?
UM: Select low-noise designs (por exemplo, step-lap core) or install soundproof enclosures.