Transformator

Transformator (Transformator) – Comprehensive Guide

1. Main Types of Trafo

(1) By Cooling Method
  • Oil-Immersed Trafo

    • Uses insulating oil for cooling, suitable for high-voltage and high-capacity applications (bijv., grid substations).

    • Common Models: ONAN (natural cooling), AAN UIT (forced air cooling), OFAF (forced oil and air cooling).

  • Dry-Type Trafo

    • Oil-free design, insulated by air or resin, ideal for fire-sensitive environments (bijv., ziekenhuizen, datacentra).

    • Common Models: SCB (epoxy resin-cast), SG (open-type).

(2) By Application
  • Distribution Trafo

    • Spanningsniveaus: 10kV/0.4kV, used for end-user power supply (bijv., residential areas, fabrieken).

  • Power Trafo

    • Voltage levels ≥110kV, used in transmission networks (bijv., substation main transformers).

  • Special Trafo

    • Includes rectifier transformers (for electrolysis), mining transformers (explosion-proof design), enz.

                        4_副本_副本 

2. Belangrijkste specificaties

ParameterBeschrijving
Nominaal vermogenbijv., 100kVA, 5000kVA; must be calculated based on load.
SpanningsverhoudingInput/output voltage (bijv., 10kV/0.4kV).
Impedantie spanningTypically 4%~10%, affects short-circuit current.
Connection Groupbijv., Dyn11 (common for distribution), Ja0 (balanced low-voltage loads).
KoelmethodeONAN, AAN UIT, OFWF (ondergedompeld in olie); AAN/UIT (droog type).
EfficiëntieklasseChinese standard (GB 20052): Klas 1 (highest efficiency), Klas 2, Klas 3.

3. Toepassingen

  • Power Systems: Voltage step-up/down, grid interconnection.

  • Industrieel: Power supply for motors, ovens (custom impedance may be required).

  • Hernieuwbare energie: PV/wind grid integration (must withstand harmonics).

  • Rail Transit: Traction transformers (25kV/50Hz).

4. Selectiegids

  • Indoor Installation: Prefer dry-type (fireproof) or fully sealed oil-immersed.

  • Outdoor Installation: Ondergedompeld in olie (protection class ≥IP55).

  • High Load Fluctuations: Choose models with strong overload capacity (bijv., ONAF cooling).

  •                  2_副本

5. Veelgestelde vragen

Q: How to choose between oil-immersed and dry-type transformers?
A: Oil-immersed offers lower cost and higher capacity but requires fire protection; dry-type is safer for confined spaces.

Q: How to calculate required capacity?
A: Sum all load power (kVA) and reserve 20%~30% margin.

Q: How to reduce transformer noise?
A: Select low-noise designs (bijv., step-lap core) or install soundproof enclosures.

Updates nieuwsbrief

Vul hieronder uw e-mailadres in en schrijf u in voor onze nieuwsbrief