Trafo (Trasformatore) – Comprehensive Guide
1. Main Types of Trafo
(1) By Cooling Method
Oil-Immersed Trafo
Uses insulating oil for cooling, suitable for high-voltage and high-capacity applications (per esempio., grid substations).
Common Models: ONAN (natural cooling), ACCESO SPENTO (forced air cooling), OFAF (forced oil and air cooling).
Dry-Type Trafo
Oil-free design, insulated by air or resin, ideal for fire-sensitive environments (per esempio., ospedali, centri dati).
Common Models: SCB (epoxy resin-cast), SG (open-type).
(2) By Application
Distribution Trafo
Voltage levels: 10kV/0.4kV, used for end-user power supply (per esempio., residential areas, fabbriche).
Power Trafo
Voltage levels ≥110kV, used in transmission networks (per esempio., substation main transformers).
Special Trafo
Includes rectifier transformers (for electrolysis), mining transformers (explosion-proof design), ecc.
2. Key Specifications
| Parametro | Descrizione |
|---|---|
| Capacità nominale | per esempio., 100kVA, 5000kVA; must be calculated based on load. |
| Voltage Ratio | Input/output voltage (per esempio., 10kV/0.4kV). |
| Impedance Voltage | Typically 4%~10%, affects short-circuit current. |
| Connection Group | per esempio., Dyn11 (common for distribution), Yyn0 (balanced low-voltage loads). |
| Cooling Method | ONAN, ACCESO SPENTO, OFWF (immerso nell'olio); ACCESO/SPENTO (di tipo secco). |
| Efficiency Class | Chinese standard (GB 20052): Classe 1 (highest efficiency), Classe 2, Classe 3. |
3. Applicazioni
Power Systems: Voltage step-up/down, grid interconnection.
Industriale: Power supply for motors, forni (custom impedance may be required).
Renewable Energy: PV/wind grid integration (must withstand harmonics).
Rail Transit: Traction transformers (25kV/50Hz).
4. Selection Guide
Indoor Installation: Prefer dry-type (fireproof) or fully sealed oil-immersed.
Outdoor Installation: Oil-immersed (protection class ≥IP55).
High Load Fluctuations: Choose models with strong overload capacity (per esempio., ONAF cooling).

5. Domande frequenti
Q: How to choose between oil-immersed and dry-type transformers?
UN: Oil-immersed offers lower cost and higher capacity but requires fire protection; dry-type is safer for confined spaces.
Q: How to calculate required capacity?
UN: Sum all load power (kVA) and reserve 20%~30% margin.
Q: How to reduce transformer noise?
UN: Select low-noise designs (per esempio., step-lap core) or install soundproof enclosures.