Основные характеристики масляных распределительных трансформаторов

Основные характеристики масляных распределительных трансформаторов

Anoil-immersed distribution transformer is a type of electrical transformer that uses insulating oil as both a coolant and dielectric medium. These transformers are widely used in power distribution networks to step down voltage levels (typically from 11kV/33kV to 415V/240V) for industrial, коммерческий, and residential applications.


         21_副本

  1. Охлаждение& Изоляция

    • Mineral oil or synthetic ester oil is used to dissipate heat and provide electrical insulation.

    • The oil also prevents oxidation and moisture absorption, extending transformer life.

  2. Construction

    • Основной: Made of laminated silicon steel to reduce eddy current losses.

    • Обмотки: Copper or aluminum conductors (ВН & LV windings).

    • Танк: Sealed or conservator-type (with a breather to prevent moisture ingress).

    • Втулки: Porcelain or polymer insulators for cable connections.

    • Radiators/Fins: Enhance cooling by increasing surface area.

  3. Типы

    • Hermetically Sealed: Fully sealed to prevent oil oxidation (no conservator).

    • Conservator-Type: Uses an oil expansion tank (реставратор)       with a breather.

    • ОНАН (Масло Натуральное Воздух Натуральное): Passive cooling (natural oil & air circulation).

    • ВКЛ ВЫКЛ (Масло Натуральное Воздушное Форсированное): Fans are added for better cooling at higher loads.

  4. Преимущества

    • Efficient heat dissipation, allowing higher load capacity.

    • Длительный срок службы (20-30 years with proper maintenance).

    • Reliable performance in varied environmental conditions.

    • Lower initial cost compared to dry-type transformers.

  5. Недостатки

    • Fire risk due to flammable oil (requires fire safety measures).

    • Regular maintenance needed (oil testing, leakage checks).

    • Environmental concerns (oil disposal, potential spills).

  6. Приложения

    • Power distribution networks (utility substations).

    • Industrial plants, Коммерческие здания, and residential complexes.

    • Renewable energy systems (solar/wind farms).

    22_副本

Maintenance Requirements

  • Oil Testing: Check dielectric strength, moisture content, and acidity.

  • Leak Inspection: Ensure no oil seepage from gaskets or welds.

  • Bushing & Winding Checks: Detect insulation degradation.

  • Sludge Removal: Prevent clogging in cooling ducts.

Standards & Certifications

  • МЭК 60076 (International standards for power transformers).

  • IEEE C57.12.00 (General requirements for liquid-immersed transformers).

  • IS 1180 (Indian Standard for oil-immersed distribution transformers).

Comparison with Dry-Type Transformers

Feature

масляный

Сухой тип

Cooling Medium

Mineral Oil

Air/Solid Insulation

Fire Risk

Higher (легковоспламеняющееся масло)

Lower (no oil)

Обслуживание

More frequent

Less frequent

Efficiency

Высокий (better cooling)

Slightly lower

Cost

Lower initial cost

Higher initial cost

Заключение

Oil-immersed distribution transformers are cost-effective and efficient for medium-to-high power distribution but require careful handling due to oil-related risks. They remain the preferred choice for outdoor and high-load applications where cooling efficiency is critical.

Обновления рассылки

Введите свой Email ниже и подпишитесь на рассылку новостей