アンoil-immersed distribution transformer is a type of electrical transformer that uses insulating oil as both a coolant and dielectric medium. These transformers are widely used in power distribution networks to step down voltage levels (typically from 11kV/33kV to 415V/240V) for industrial, コマーシャル, および住宅用アプリケーション.

冷却& 絶縁
Mineral oil or synthetic ester oil is used to dissipate heat and provide electrical insulation.
The oil also prevents oxidation and moisture absorption, extending transformer life.
Construction
コア: Made of laminated silicon steel to reduce eddy current losses.
巻線: Copper or aluminum conductors (HV & LV windings).
タンク: Sealed or conservator-type (with a breather to prevent moisture ingress).
ブシュ: Porcelain or polymer insulators for cable connections.
Radiators/Fins: Enhance cooling by increasing surface area.
種類
Hermetically Sealed: Fully sealed to prevent oil oxidation (no conservator).
Conservator-Type: Uses an oil expansion tank (保存者) with a breather.
オナン (オイル ナチュラル エア ナチュラル): Passive cooling (natural oil & air circulation).
オンオフ (オイル ナチュラル エア フォース): Fans are added for better cooling at higher loads.
利点
効率的な放熱, allowing higher load capacity.
長寿命 (20-30 years with proper maintenance).
Reliable performance in varied environmental conditions.
Lower initial cost compared to dry-type transformers.
短所
Fire risk due to flammable oil (requires fire safety measures).
Regular maintenance needed (oil testing, leakage checks).
Environmental concerns (oil disposal, potential spills).
アプリケーション
Power distribution networks (utility substations).
産業プラント, 商業ビル, and residential complexes.
再生可能エネルギーシステム (太陽光発電/風力発電所).

メンテナンス要件
Oil Testing: Check dielectric strength, moisture content, そして酸味.
Leak Inspection: Ensure no oil seepage from gaskets or welds.
Bushing & Winding Checks: Detect insulation degradation.
Sludge Removal: Prevent clogging in cooling ducts.
規格 & 認証
IEC 60076 (International standards for power transformers).
IEEE C57.12.00 (General requirements for liquid-immersed transformers).
IS 1180 (Indian Standard for oil-immersed distribution transformers).