Anoil-immersed distribution transformer is a type of electrical transformer that uses insulating oil as both a coolant and dielectric medium. These transformers are widely used in power distribution networks to step down voltage levels (typically from 11kV/33kV to 415V/240V) for industrial, வணிக, and residential applications.


         21_副本

  1. குளிர்ச்சி& காப்பு

    • Mineral oil or synthetic ester oil is used to dissipate heat and provide electrical insulation.

    • The oil also prevents oxidation and moisture absorption, extending transformer life.

  2. Construction

    • கோர்: Made of laminated silicon steel to reduce eddy current losses.

    • முறுக்குகள்: Copper or aluminum conductors (எச்.வி & LV windings).

    • Tank: Sealed or conservator-type (with a breather to prevent moisture ingress).

    • புஷிங்ஸ்: Porcelain or polymer insulators for cable connections.

    • Radiators/Fins: Enhance cooling by increasing surface area.

  3. வகைகள்

    • Hermetically Sealed: Fully sealed to prevent oil oxidation (no conservator).

    • Conservator-Type: Uses an oil expansion tank (காப்பாளர்)       with a breather.

    • ஓனான் (எண்ணெய் இயற்கை காற்று இயற்கை): Passive cooling (natural oil & air circulation).

    • ஆன் ஆஃப் (Oil Natural Air Forced): Fans are added for better cooling at higher loads.

  4. நன்மைகள்

    • Efficient heat dissipation, allowing higher load capacity.

    • நீண்ட சேவை வாழ்க்கை (20-30 years with proper maintenance).

    • Reliable performance in varied environmental conditions.

    • Lower initial cost compared to dry-type transformers.

  5. தீமைகள்

    • Fire risk due to flammable oil (requires fire safety measures).

    • Regular maintenance needed (oil testing, leakage checks).

    • Environmental concerns (oil disposal, potential spills).

  6. விண்ணப்பங்கள்

    • Power distribution networks (utility substations).

    • Industrial plants, வணிக கட்டிடங்கள், and residential complexes.

    • Renewable energy systems (solar/wind farms).

    22_副本

Maintenance Requirements

  • Oil Testing: Check dielectric strength, moisture content, and acidity.

  • Leak Inspection: Ensure no oil seepage from gaskets or welds.

  • Bushing & Winding Checks: Detect insulation degradation.

  • Sludge Removal: Prevent clogging in cooling ducts.

Standards & Certifications

  • IEC 60076 (International standards for power transformers).

  • IEEE C57.12.00 (General requirements for liquid-immersed transformers).

  • IS 1180 (Indian Standard for oil-immersed distribution transformers).

Comparison with Dry-Type Transformers

அம்சம்

Oil-Immersed

Dry-Type

Cooling Medium

Mineral Oil

Air/Solid Insulation

Fire Risk

உயர்ந்தது (எரியக்கூடிய எண்ணெய்)

கீழ் (எண்ணெய் இல்லை)

பராமரிப்பு

More frequent

Less frequent

திறன்

உயர் (better cooling)

Slightly lower

Cost

Lower initial cost

Higher initial cost

முடிவுரை

Oil-immersed distribution transformers are cost-effective and efficient for medium-to-high power distribution but require careful handling due to oil-related risks. They remain the preferred choice for outdoor and high-load applications where cooling efficiency is critical.