1P52S 314Ah LiFePO4 BESS Module 166.4V 52.25kWh

1P52S 314Ah LiFePO4 BESS module with 166.4V, 52.25kWh, 0.5C continuous current and CMU monitoring for high-voltage energy storage systems.

PRODUCT DETAILSGet a Bulk Quote

Figure 1. 1P52S 314Ah LiFePO4 BESS module, 166.4V / 52.25kWh, 1,060 × 780 × 245mm, featuring a covered top busbar and lifting handles. Rendered product visual; not an actual production photograph.

1. Product Overview

The 1P52S 314Ah LiFePO4 BESS Module is a high-voltage battery module designed for integration into large-scale energy storage systems.

Built with 52 LFP cells connected in series, the module provides a nominal voltage of 166.4V, a rated capacity of 314Ah, and a nominal energy of approximately 52.25kWh.

The module measures 1,060 × 780 × 245mm and weighs approximately 335kg. Its aluminium enclosure features a covered top busbar, lifting handles, and mounting feet for rack or container installation.

The module uses a Cell Monitoring Unit (CMU) to collect cell voltage and temperature data and transmit the information to an external rack-level or container-level Battery Management System (BMS). System-level functions, such as contactor control, pre-charge, current monitoring, and main protection, are handled by the external battery control system.

For suitable system designs, eight modules connected in series form a 416S battery string with a nominal voltage of 1,331.2V and approximately 418kWh of nominal energy. Multiple strings can then be integrated into a larger energy storage system, subject to PCS compatibility and system design requirements.

Important: This is a high-voltage DC battery module, not a standalone energy storage system. It requires compatible external battery management, protection, power conversion, and thermal management equipment.

2. Key Features and Benefits

  • 52.25kWh nominal energy: High energy capacity in a single 1P52S battery module.
  • 166.4V nominal voltage: Designed for high-voltage energy storage system architectures.
  • 314Ah LFP cells: Uses 52 cells connected in series.
  • 0.5C continuous operation: Rated continuous charge and discharge current of 157A, subject to operating conditions.
  • CMU cell monitoring: Collects individual cell voltage and temperature data for external battery management.
  • Covered top busbar: Insulated cover helps reduce the risk of accidental contact with live electrical connections during handling and maintenance.
  • Aluminium enclosure: Designed for integration into compatible battery racks and containerized storage systems.
  • Heavy-duty handling design: Lifting handles and mounting features support mechanical installation using suitable lifting equipment.
  • Modular system integration: Multiple modules can be connected in series and parallel according to the approved system architecture.

3. Technical Specifications

Table 1. Technical specifications of the 1P52S 314Ah LiFePO4 BESS Module. Values are typical configuration data and must be confirmed against the approved production datasheet.

Electrical Specifications

Parameter

Specification

Battery chemistry

LiFePO4 (LFP)

Configuration

1P52S

Number of cells

52

Nominal voltage

166.4V

Operating voltage range

130.0–189.8V

Nominal capacity

314Ah

Nominal energy

52.25kWh

Usable energy

Approx. 49.64kWh at 95% DoD (calculated)

Continuous charge current

157A (0.5C)

Continuous discharge current

157A (0.5C)

Peak discharge current

314A (1C) for 10 seconds

Module DC internal resistance

≤30mΩ (1kHz, 25°C, 50% SoC)

Cycle life

≥8,000 cycles to 80% SoH at 0.5C/0.5C, 25°C (cell-level reference)

Monitoring and Protection

Parameter

Specification

Monitoring unit

CMU (Cell Monitoring Unit)

Monitoring functions

Cell voltage and temperature monitoring

Communication

Isolated local communication bus (protocol to be confirmed)

System-level BMS

External rack-level or container-level BMS

Contactor control

External system

Pre-charge control

External system

Main current monitoring

External system

Main protection

Designed at rack or container level

Mechanical and Environmental Specifications

Parameter

Specification

Dimensions (W × D × H)

1,060 × 780 × 245mm

Approximate weight

335kg

Enclosure material

Aluminium

Busbar design

Covered top busbar

Installation features

Lifting handles and mounting feet

Ingress protection

IP20 module enclosure (confirm test rating)

Charging temperature

0 to +55°C

Discharging temperature

−20 to +55°C

Storage temperature

−10 to +35°C

Storage condition

Up to 12 months at 25°C and 30–50% SoC (subject to manufacturer guidance)

Note: The voltage range is calculated from the stated cell limits of 2.50V and 3.65V across 52 cells. Actual operating limits and protection thresholds must follow the approved BMS and system specifications.

4. Module Architecture and Monitoring Interface

The module consists of 52 LFP cells connected in series, forming a 1P52S configuration. The nominal voltage is 166.4V, and the rated capacity is 314Ah.

A CMU sampling board monitors individual cell voltages and temperatures. The collected data is transmitted to the external rack-level or container-level BMS through an isolated communication interface.

Unlike a complete battery system, this module does not independently provide all system-level protection and switching functions. The external battery management system is responsible for functions such as:

  • Contactor and relay control.
  • Pre-charge management.
  • Main current measurement.
  • String-level voltage and current monitoring.
  • System protection and fault management.
  • Coordination with the PCS and thermal management system.

The top busbar is protected by an insulating cover. This design helps reduce accidental contact with electrical connections during handling and maintenance. However, the module must still be isolated and verified as de-energized before service. The cover does not make live maintenance safe.

At approximately 335kg, the module must be handled using suitable lifting equipment. Installation procedures, lifting points, and rack support requirements should follow the manufacturer's instructions.

5. System Integration and Capacity Expansion

The 1P52S module is designed for integration into high-voltage battery systems. Modules can be connected in series to achieve the required DC voltage, while multiple strings can be connected in parallel to increase total system capacity.

Example: Eight Modules in Series

Connecting eight 1P52S modules in series produces the following theoretical configuration:

Parameter

Value

Number of modules

8

Total cell configuration

416S

Nominal voltage

1,331.2V

Nominal capacity

314Ah

Nominal energy

Approx. 418.00kWh

Continuous current

157A

Peak discharge current

314A for 10 seconds, subject to system limits

Example: Twelve Parallel Strings

If twelve identical 416S strings are connected in parallel, the theoretical system configuration is:

Parameter

Value

Number of strings

12

Total number of modules

96

Total cell configuration

416S × 12P at string level

Total nominal energy

Approx. 5,015.96kWh

Total nominal energy

Approx. 5.02MWh

Total cell quantity

4,992

These figures are theoretical calculations, not a standard or guaranteed container configuration. Actual system capacity, DC voltage limits, string quantity, and PCS compatibility must be confirmed by the system designer.

System Integration Considerations

Before connecting modules into a high-voltage battery system, confirm:

  • PCS DC voltage operating range and maximum voltage.
  • Battery string configuration and system voltage limits.
  • Rack-level and container-level BMS compatibility.
  • CMU communication protocol and wiring requirements.
  • String fuses, DC circuit breakers, and isolation devices.
  • Busbar design, cable sizing, and insulation coordination.
  • Pre-charge and contactor control strategy.
  • Grounding, insulation monitoring, and emergency shutdown design.
  • Thermal management and fire protection requirements.
  • Applicable system-level testing and certification.

High-voltage safety: The module can reach 189.8V at the stated maximum cell voltage. A series string of eight modules can reach 1,518.4V at this limit. The PCS, switching equipment, insulation system, and protection devices must therefore be selected based on the maximum system voltage, not only the nominal voltage.

6. Charging, Installation and Operating Guidelines

The module is intended for use in professionally designed high-voltage energy storage systems.

For safe integration and reliable operation:

  • Use a compatible rack-level or container-level BMS.
  • Follow the approved cell voltage and temperature limits.
  • Confirm the maximum charge and discharge current before system commissioning.
  • Use suitable high-voltage DC fuses, disconnects, and circuit breakers.
  • Ensure all busbar and cable connections meet the specified electrical and mechanical requirements.
  • Provide suitable insulation, grounding, and electrical clearance.
  • Install the module in a rack or enclosure designed to support its weight.
  • Use approved lifting equipment and follow the specified lifting procedure.
  • Provide appropriate ventilation or liquid cooling according to the system thermal design.
  • Isolate the battery system and verify the absence of voltage before maintenance.

The stated 157A continuous current is a module-level rating. The actual system operating current must also comply with the limits of the BMS, PCS, cables, busbars, protection devices, and thermal management system.

7. Applications

The 1P52S 314Ah LiFePO4 BESS Module is designed for integration into high-voltage energy storage systems, including:

  • Utility-scale battery energy storage systems.
  • Containerized energy storage systems.
  • Commercial and industrial energy storage projects.
  • Grid-connected energy storage applications.
  • Renewable energy storage systems.
  • Large-scale battery rack systems.

The final system configuration depends on project voltage requirements, PCS compatibility, installation conditions, and applicable safety standards.

8. Certifications and Technical Documentation

For high-voltage battery projects, documentation should clearly distinguish between cell-level, module-level, and complete-system test reports.

Recommended Documentation

Document

Scope

Recommended Page Placement

Module Datasheet

Electrical, mechanical, environmental, and communication specifications

Product page download

UN38.3 Test Summary

Lithium battery transport testing

Product page download

IEC 62619 Report

Industrial lithium battery safety, where the report covers the applicable battery configuration

Download block when available

IEC 63056 Report

Safety requirements for lithium batteries used in electrical energy storage systems, according to the report scope

Relevant cell or battery system page

UL 1973

Battery safety listing for applicable battery products or systems

Badge only if the exact product is within the listing scope

UL 9540A Test Report

Thermal runaway fire propagation test results for the tested battery or energy storage configuration

System or container page, unless the report specifically covers this module

CE Declaration

Applicable EU conformity requirements for the actual product

Download block when available

RoHS Report

Restricted substances compliance

Download block when available

SDS / MSDS

Safety information for battery handling and transport

Download block

Certification note: Do not present a cell-level report as proof that the complete module or container system is certified. UL 9540A is a test method for evaluating thermal runaway fire propagation; it should not be described as a standalone product certification. Any certificate or report displayed on this page must match the actual product, configuration, and testing scope.

ISO 9001 should be displayed on the company or factory page as a quality management system certification, not as a product certification.

9. Media and Trust Assets

The product page should include clear technical images and real manufacturing evidence to help buyers evaluate the module.

Product Images

  • Main product image showing the complete module and covered top busbar.
  • Front and side views showing the enclosure structure.
  • Close-up of the busbar cover and electrical connection points.
  • Lifting handle and mounting foot details.
  • Product dimension drawing.
  • Internal cell arrangement and CMU interface diagram.

Factory and Quality Control Photos

Use real production photographs wherever possible:

  • 52S module assembly and busbar connection.
  • Busbar insulation and electrical inspection.
  • CMU installation and wiring.
  • Cell voltage and temperature monitoring tests.
  • End-of-line electrical testing.
  • Rack-level integration and string testing.

Technical Documents and Test Evidence

Display document thumbnails with the issuing laboratory, report number, product model, and test scope clearly visible.

Recommended downloads include:

  • Module datasheet PDF.
  • Applicable UN38.3 test summary.
  • Relevant IEC test reports, if available.
  • SDS / MSDS.
  • Applicable compliance declarations.
  • System-level test reports, where relevant and clearly identified.

Only use actual reports and valid certificates. Do not display placeholder certificate numbers as if they were issued documents.

10. Frequently Asked Questions

Q1: What is the nominal energy of the 1P52S 314Ah BESS module?

A: The module has a nominal voltage of 166.4V and a rated capacity of 314Ah, providing approximately 52.25kWh of nominal energy.

Q2: How many modules are required for a 5MWh energy storage system?

A: One possible configuration uses eight modules in series per string and twelve strings in parallel. This gives 96 modules and approximately 5.02MWh of nominal energy. The final configuration must be checked against the PCS voltage range, system design, and project requirements.

Q3: Does this module include a complete BMS?

A: The module includes a CMU sampling board for cell voltage and temperature monitoring. The main BMS functions, including contactor control, pre-charge, and system-level protection, are handled by an external rack-level or container-level BMS.

Q4: Can this module be used in a 48V battery system?

A: No. This module has a 1P52S configuration and a nominal voltage of 166.4V. For 48V-class battery systems, a compatible 16S battery module should be selected.

Q5: Can multiple modules be connected in series?

A: Yes. Series connection can increase the total DC voltage. For example, eight modules in series provide a nominal voltage of 1,331.2V. The maximum series quantity must be approved by the battery system designer and confirmed against the PCS and protection equipment ratings.

Q6: Is this module suitable for containerized energy storage systems?

A: It is designed for integration into high-voltage energy storage systems, including containerized projects. The complete system requires compatible battery management, power conversion, protection, and thermal management equipment.

Q7: What is the MOQ and lead time?

A: MOQ and lead time depend on the project configuration, order quantity, and production schedule. Please contact us with your required system capacity and technical specifications for a quotation.

11. Request a Quotation

Looking for a high-voltage LiFePO4 battery module for a utility-scale or commercial energy storage project?

Send us your project requirements, including target energy capacity, DC voltage range, PCS model, battery configuration, and required documentation.

Our team can help evaluate the module configuration and provide technical information for your energy storage project.

Contact us for technical specifications, pricing, and project support.

Send Your Inquiry Today

1P52S 314Ah LiFePO4 BESS Module 166.4V 52.25kWh

Fields marked * are required.

Send Your Inquiry Today

Tell us about your application and requirements. Our team will review your request.

Fields marked * are required.